Strona głównaS355JR or S355J2 – part 2

S355JR or S355J2 – part 2

Last time we talked about the Charpy test. This time let’s take it further.

STEP BY STEP…

The Eurocode defines the fracture energy to be assumed for a tested steel specimen. It is 27 J, and at this energy the steel is tested at different temperatures until it cracks under dynamic load. So we already have two variables: the energy needed to break the specimen and the design temperature. There is a third one as well – thickness. Fracture toughness decreases as material thickness increases. In other words, a thick plate is less resistant to cracking than a thin one. We will go through the details of this next time… For now – take our word for it.

The design temperature for a building depends on the location of the steel elements – whether they are inside or outside. For interiors, unless specified otherwise, about −5 °C can be assumed. For external elements, the detailed criteria are given in the NA to EN 1991-1-5. For Poland the NA gives them as a map (see the picture above). For Wrocław it is −32 °C.

OK, there you have it – input data collected. What next?

Table 2.1 from EN 1993-1-10 specifies maximum permissible values of element thickness in [mm] taking into account steel grade (S235/S275/S355…), the minimum required fracture energy (typically 27 J), the stress level in the element under the design load – 0.75fy / 0.5fy / 0.25fy – and the design temperature.

So let’s see what maximum thickness may be used “outside” for S355JR in Wrocław, Poland, for a column loaded to 0.75fy – that is, very heavily utilised:

Table of permissible element thicknesses by steel grade and reference temperature, with the S355 row marked
The permissible thickness falls together with the design temperature.

It is only 15 mm, so with S355JR the largest possible column is HEB200. For comparison – with S355J2 the maximum thickness is 40 mm (i.e. HEM320).

That is a big difference!

The Polish NA to EN 1993-1-10 gives no other way of assigning a steel grade. That is not the case for BS EN 1993-1-10 and SCI Publication P419, which allow steel grades to be assigned differently when the load on the structure is quasi-static (that is, most of the load comes from dead loads rather than live or wind loads):

SCI P419:

The same table in a different edition – the value for S355JR at minus 30 degrees marked
For the same grade and temperature, editions of the standard give different values – it is worth checking which one you use.

Under the BS EN national annex the permissible thickness for S355JR would be as much as 54 mm instead of 15 mm. That is a valuable gain. For S355J2 it can be as much as 200 mm! It all comes down to dynamic loads and brittle fracture – quasi-static loads make far smaller demands.

We will talk about brittle fracture soon.